35u Rack Outdoor Power Cabinet One Front Door with Air Conditioner Fan

Type: Power Distribution Cabinet
Structure: Customization
Certification: ISO9001:2000, CCC
Form: Customization
Operation Voltage: Customization
Size: H1970mm×w680mm×d1290mm or Customizati
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
DX231726812919035
Application Range
Electric Industry
Shell Material
Galvanized Steel, Single Wall
Shell Protection Grade
IP55
Brand
Szdxzh
Transport Package
Wooden Case; Carton Onto Pallet
Specification
H1970mm×W680mm×D1290mm or Customizati
Trademark
SZDXZH
Origin
Guangdong, China
Production Capacity
3, 000 Sets Per Month

Product Description

Product Details:
Place of Origin: Shenzhen, China (Mainland)
Brand Name: SZDXZH
Certification: ISO9001, CE, 3C, FCC, TLC, IP55
Model Number: DX231726812919035
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiation
Packaging Details: Wooden case; carton onto pallet
Delivery Time: 15-20 working days
Payment Terms: L/C, D/A, D/P, MoneyGram, T/T
Supply Ability: 3,000 sets per month

Detailed Product Description
 
Demension: H1970mm×W680mm×D1290mm Type: Power Distribution Cabinet
Warranty: 1 Year Material: Galvanized Steel, Single Wall
Insulation Material: 20mm PEF Equipment Rack: 19 Inch Rack
Compartment: 1 Door: With One Front Door
LED: 48VDC IP Level: IP55
Cooling System: Air Conditioner Usage: Electric Industry
High Light: Front Door Outdoor Power Cabinet

Outdoor Power Cabinet IP55

35U Outdoor Battery Cabinet

1. Outdoor Power Cabinet Specifications
 
  • Brief introduction
DX231726812919035 is an outdoor cabinet which can protect customer's equipments from damage and extreme weather conditions.
The cabinet is an ideal solution for physical connections of outdoor telecommunication equipments. Both active telecom equipments and passive telecom equipments can be accommodated inside the cabinet.
  •  

Features

  •  
(1) The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment.
(2) The cabinet cooling use one air conditioners, which work in alternation to continuously keep thermostatic inside the cabinet.
(3) The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. At the bottom of the cabinet, there are entrance holes individually for power cable, signal cable and optical cable.
(4) All the cables, sealing and heat insulation used in the cabinet are made from flame retardant materials.
(5) The cabinet uses assembled structure, easy for installation.
(6) The cabinet includes 19" standard installation rack.
 

2. Technical Specs

  •  
Material: good quality galvanized steel
  •  
  •  
Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.
  •  
  •  
Cabinet load bearing: ≥600kg
  •  
  •  
Ingress protection: IP55
  •  
  •  
Flame retardance: comply with GB5169.7 test A
  •  
  •  
Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2×104M/500V(DC).
  •  
  •  
Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.
  •  
  •  
Mechanical strength: each surface can bear upright pressure >980N; after the door is
  •  
 
3. Technical Parameters
 
Configuration Item Technical Parameter
Cabinet Model DX231726812919035
Protection Level IP65
External Dimension H1970mm×W680mm×D1290mm
Internal Dimension 19 inch rail, 35U
Material Galvanized steel, 1.2mm thickness, single wall.
Thickness of bearing parts: 2.0mm
Insulation PEF
Coating Polyester powder coating
Color RAL7035
Lock Anti-theft four-point locking system
Hinge Inner hinge
Installation Options Floor mounted, roof mounted ,wall mounted .
Cable Routing Cable in and out from the bottom of cabinet
Maintenance One front door and one rear door
Cooling Air conditioner 2000W 48VDC
auxiliary fan DC 48V ,
Adjustable temperature (with fan temperature control)
Power distribution unit 1. Ac switchboard with transient voltage suppressor diode (SPD 80KA)
Power grid and diesel generators (L1, L2, N, G)
120V Nema 5-15R 2-position socket
1, double circuit breaker 100A
2, single circuit breakers 64A
3, single circuit breakers 30A
2. Power distribution unit
Input voltage: AC 220V (L1, L2, N and G) 60Hz
Single phase (L1, L2, N and Earth)
3. Connect the generator
Input voltage: AC 220V (L1, L2, N and G) 60Hz
 
Others Illumination LED lamp: 220VAC 50Hz
Environment Working Temperature -40ºC ~+55ºC (+Solar Radiation)
Storage Temperature -40ºC~+70ºC
Working Humidity 5%~95%(No condensation)
Working Altitude 0~4000 meters
 
 
4.Telecom cabinet installation typically involves the following steps:
 
  1. Site survey and preparation: Before installing the cabinet, the site needs to be surveyed to ensure it is suitable for the installation. This includes checking that the site is level, free from obstructions, and has adequate ventilation and power supply.
  2. Cabinet assembly: The cabinet is usually delivered in several pieces and needs to be assembled on site. This involves attaching the base, sides, and top panels, as well as installing any shelves, cable management systems, and other accessories.
  3. Cable routing: Once the cabinet is assembled, the next step is to route the cables that will connect the equipment inside the cabinet to the outside world. This may involve running cables through conduits, cable trays, or other cable management systems.
  4. Equipment installation: After the cables are routed, the equipment can be installed inside the cabinet. This may include servers, switches, routers, power supplies, and other hardware.
  5. Testing and commissioning: Once the equipment is installed, it needs to be tested and commissioned to ensure it is functioning correctly. This may involve running diagnostic tests, configuring network settings, and verifying connectivity.
  6. Documentation and handover: Finally, the installation needs to be documented, and the site handed over to the customer. This includes providing as-built documentation, test reports, and other relevant information.
 

5. Connection and Fastening

(1) Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
(2) Door hinges use inner hinge mode.

6. Appearance and Surface Treatment

Cabinet surface coating is outdoor special powder coating, with white gray color (PANTONE 428C). The coating complies with GB/T 3181-2008 requirement.

7. Quality Control Introduction
 
Quality control is an essential aspect of telecom cabinet manufacturing to ensure that the final product meets the required standards and specifications. The following are some common quality control measures that are typically taken during the production of telecom cabinets:
1.Raw material inspection: The quality control process begins with the inspection of raw materials used in the production of the cabinet. This includes inspecting the metal sheets, screws, hinges, and other components to ensure that they meet the required quality standards.
2.Production process inspection: During the production process, the cabinets are inspected at various stages to ensure that they meet the required specifications. This includes checking the dimensions, angles, and tolerances of the cabinet components.
3.Surface finish inspection: The surface finish of the cabinet is also inspected to ensure that it is free from any scratches, dents, or other defects that may affect the overall appearance and functionality of the product.
4.Functionality testing: Once the cabinet is fully assembled, it undergoes functional testing to ensure that it can perform its intended functions. This includes testing the cooling system, power supply, and other components to ensure that they are working correctly.
5.Packaging and shipment inspection: The final step in the quality control process involves inspecting the packaging of the cabinet to ensure that it is adequately protected during shipment. This includes checking for any damages or defects that may have occurred during the shipment process.

 
 
Our company resolutely implements the principle of quality first, we control and supervise the whole production process in strict accordance with the requirements of the ISO9001 system and the related implementation process. The quality department strictly controls all aspects like material inspection, production processes, product testing, shipment inspection and establishes traceable documents and product identification.
Our quality inspection team, is very familiar with the various standards, strict implementation of the standards required sampling and testing methods.
 



8. Cabinet pictures
35u Rack Outdoor Power Cabinet One Front Door with Air Conditioner Fan35u Rack Outdoor Power Cabinet One Front Door with Air Conditioner Fan35u Rack Outdoor Power Cabinet One Front Door with Air Conditioner Fan35u Rack Outdoor Power Cabinet One Front Door with Air Conditioner Fan35u Rack Outdoor Power Cabinet One Front Door with Air Conditioner Fan



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
53
Year of Establishment
2019-02-22